Nominal Range: 0-10 000ppm Maximum Overload: 20 000ppm Expected Operating Life: Two years in air Output Signal: 0.003 ± 0.001 ?A/ppm Resolution: 10ppm Temperature Range: -20°C to +50°C Pressure Range: Atmospheric ± 10% Pressure Coefficient: 0.006 % signal/mBar T90 Response Time: <70 seconds Relative Humidity Range: 15 to 90% non-condensing Typical Baseline Range (pure air): +2 to -150ppm equivalent Maximum Zero Shift (+20°C to +40°C): -150ppmequivalent
Long Term Output Drift: <2% signal loss/month Recommended Load Resistor: 10 ? Bias Voltage: Not required Repeatability: 2% of signal Output Linearity: Linear